Needle bar Adjustment (Brother BAS-326G)

Adjusting the needle bar height: Turn the machine pulley to move the needle bar to the lowest position. Then remove the rubber plug (2), loosen the screw (3) and then move the needle bar...

CONTROL BOX AND MOTOR

Motor: Disconnect the motor connector 4P (1) from the control box. Measure the resistance of the motor connector (1) using an ohmmeter in the x 1 range. If the value is as shown in...